Outdoor Unit; Removal Of Outer Panels - Daikin H Series Service Manual

Inverter pair wall mounted type
Hide thumbs Also See for H Series:
Table of Contents

Advertisement

SiUS04-924_A

2. Outdoor Unit

Note:
The illustrations represent heat pump models.
2.1

Removal of Outer Panels

Procedure
Step
1. Features
2. Remove the suction grille.
1
Release the 3 hooks at
the upper first, and then
3 hooks at the middle.
2
Release the 3 hooks at
the bottom and remove
the suction grille.
156
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
(R9749)
 The hooks are secured in the
clearances of the outdoor heat
exchanger fins.
Suction grille
(R9586)
(R9587)

Outdoor Unit

Points
Removal Procedure

Hide quick links: