Removal Of Electrical Box - Daikin 3MKD75BVMA8 Service Manual

5.8/6.8/7.1/7.5 kw class
Table of Contents

Advertisement

Si12-793

2. Removal of Electrical Box

Procedure
Step
1. Remove the connecting
wires.
1
The figure shows the
connecting wires.
2
Remove the terminal
board fixing screw.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Electrical box
Electronic expansion
valve coils
Outdoor temperature thermistor
Gas pipe
Liquid
pipe
Terminal board fixing screw
A port
C port
B port
Wire fixing plate
Service monitor PCB
A port
B port
C port
Service port
(R3063)
(R2163)
Match the colors of the
Power supply
connection wires to A, B and
(L)–White
(N)–Black
C ports as follows.
(1) Black: Power supply
(2) White: Power supply
(3) Red: Transmission
The wires are fixed to the
Earth / ground
wire
terminal board with screws.
(R17637)
Removal of Electrical Box
Points