Installing and replacing option cards

This section provides information about the optimal placement of option cards in
the Contivity 5000 and instructions for installing option cards.

Considerations for installing option cards

The Contivity 5000 has six slots for option cards (see
These slots are connected to three separate buses

Figure 27 Contivity 5000 option card slots and buses

Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
The 1000BASE-T, 1000BASE-SX, and CSA cards are high-speed cards; most
other option cards are low-speed (33-bit/33-MHz) cards. To maximize system
performance, reserve slots 1, 2, and 6 for high-speed cards, and install low-speed
cards in slots 3, 4, and 5. (The SSL VPN Module 1000 must be installed in slot 1.)
Chapter 4 Installing option cards and field replaceable units 69
Slots 1 and 2 are connected to the 64-bit/100-MHz bus (Bus 1).
Slots 3, 4, and 5 are connected to the 32-bit/33-MHz bus (Bus 2).
Slot 6 is connected to the 64-bit/133-MHz bus (Bus 3).
(Figure
DIMMs
Bus 1
64-bit, 100 MHz
Bus 2
32-bit, 33 MHz
Bus 3
64-bit, 133 MHz
Figure 25 on page
67).
27).
11357EA
Installing the Contivity 5000