Verifying checksum ...
Upgrade completed OK
Reboot the pack to run new loadware
The <userid> and <password> are those of the FTP server and the
<path> is the path to the file on the FTP Server.
4 After the upgrade is complete, enable the card from overlay 32 on the
switch software
5 Restart the card.
6 After the card is restarted, at the shell, type:
swVersionShow <CR>
This command displays the current software version running on the card.
For example:
softwareRev: CRC Rel: 0.01
Loadware upgrade using the PCMCIA Card to transfer loadware
to the compact flash card
Use this procedure to upgrade the loadware from the local /C:/ drive
Compact flash card.
1 Disable the card using overlay 32 on the switch software.
2 Insert the PCMCIA card into the faceplate PCMCIA card slot.
3 Copy loadware from the PCMCIA card (/A:/ drive) to the compact flash
card (/C:/ drive) as shown in the following example:
copy("/A:/newexec","/C:/newexec")
Planning, Installation, and Administration Guide
Program filename =
Checksum =
length =
/C:/exec
0xdef4797d
0x59d1fc
Upgrade Procedures
The checksum value
varies between software
loads. Consult the release
notes for the applied
upgrade load to identify
the correct value.