Application Loadware Upgrade - Nortel Call Recording Card User Manual

Nortel call recording software: user guide
Table of Contents

Advertisement

Upgrade Procedures

Application loadware upgrade

The loadware is located on the compact flash drive as the file C:/exec. To
upgrade the card, the contents of this file must be overwritten with the new
target load. There are three recommended methods for performing this task:
1. "Loadware upgrade from an external FTP server," on page 64.
2. "Loadware upgrade using the PCMCIA Card to transfer loadware to the
compact flash card," on page 65.
3. "Loadware upgrade using FTP to transfer the loadware to the compact
flash card," on page 67.
You must access VxWorks shell to upgrade the card. This is available either
through a telnet connection or through serial access to COM1. For shell
access, the default user name is crcadmin and the default password is
crcsecurity. See "VxWorks shell," on page 59 for more information.
Loadware upgrade from an external FTP server
Use the following procedure to perform a loadware upgrade from an
external FTP server.
1 Copy the loadware to an FTP server.
2 Disable the card using overlay 32 on the switch software.
3 Perform the upgrade using the upgrade command from the shell as
shown in the following example:
upgrade("<Server IP Address>", "<userID>", "<password>",
"<path>","newexec")
value = 0 = 0x0
Connecting to <Server IP Address>...
connected to <Server IP Address> OK
File Length = 0x0059d1fc
Bank Size = 0x00780000
Updating sector:
0..1..2..3..4..5..6..7..8..9..10..11..12..13..14..15..16..1
64
Standard 1.0
Nortel Call Recording Card