Toshiba MMU-UP0071MH-UL Service Manual page 149

Hide thumbs Also See for MMU-UP0071MH-UL:
Table of Contents

Advertisement

No. Part name
1. Detachment
PMV coil
1) Following step 1 of
the parts.
2) Remove the PMV connector : CN082 (6P Blue) from
the P.C.board.
3) Turn the PMV coil slightly clockwise while holding the
PMV body so that the body does not turn, and remove
the PMV coil in the arrow direction.
2. Attachment
1) Attach the PMV coil as before and check it does not
move.
NOTE
Check the direction of the PMV coil.
Check the claw holes in the PMV coil are securely placed
into four claws on the PMV body.
Check the position of the lock part on the binding band
fixing the lead wires.
2) Attach the PMV connector : CN082 (6P Blue)
3) Following step 1 of
original in the reverse procedure.
Procedure
and those in 3) to 5), detach
and 1), attach the parts as
Lead wire
(with protective tube)
Binding band
Ensure that the lock part on the binding
band comes to the position in the figure.
Attach the PMV coil to the PMV body so that the
PMV coil protrusion part points to the PMV body inlet.
Fit the claw holes on the PMV coil into four claws on
the PMV body.
PMV body inlet
Caution when fixing the lead wire with the
binding band.
. Do not apply tension to the drawing
part on the coil lead wire.
. Insert the protective tube up to the
root of drawing part on the lead wire.
. Ensure that the PMV pipe does not
come to contact with the protective tube.
– 149 –
Remarks
PMV motor
Turing direction
PMV coil
PMV body