Dell PowerEdge XR4520c Installation And Service Manual page 105

Table of Contents

Advertisement

Steps
1. Power off the compute sled and remove the compute sled from chassis.
2. Move the DIP switch on the system board from switches 1 and 2 to switches 2 and 3.
NOTE:
Use a plastic scribe to change the DIP switch settings.
NOTE:
The existing passwords are not disabled (erased) until the system boots with the DIP switch on switches 2 and
3. However, before you assign a new system and/or setup password, you must move the DIP switch back to switches 1
and 2.
NOTE:
If you assign a new system and/or setup password with the DIP switch on switches 2 and 3, the system disables
the new password(s) the next time it boots.
3. Insert compute sled into chassis and power on the compute sled.
4. Power off the compute sled and remove the compute sled from chassis.
5. Move the DIP switch on the system board from switches 2 and 3 to switches 1 and 2.
6. Insert compute sled into chassis and power on the compute sled.
7. Assign a new system and/or setup password.
DIP Switches
105