Table 5: Required Actions Before Removing a FRU from the PTX1000

FRU
Power supplies (4)
Fan modules (3)
Optical transceivers

PTX1000 Port Panel

22
CAUTION:
Replace a failed fan module with a new fan module within 30
seconds of removal to prevent chassis overheating.
Table 5 on page 22
lists the FRUs for the PTX1000 and actions to take before removing
them.
Required Actions Before Removal
Remove the power cord or cable for the power supply unit.
NOTE:
You need a minimum of two powered power supplies for the PTX1000 to operate
properly.
None.
None. We recommend that you disable the interface by using the set interfaces
interface-name disable command before you remove the transceiver. See
a Fiber-Optic Cable from the PTX1000" on page
See
Figure 3 on page 22
for the location of the power supplies and fan modules on the
FRU panel of the PTX1000.

Figure 3: FRUs on the FRU Panel in a PTX1000

1—
Power supplies (4)
NOTE:
If you have a Juniper Care service contract, register any addition,
change, or upgrade of hardware components at
https://www.juniper.net/customers/support/tools/updateinstallbase/
to do so can result in significant delays if you need replacement parts. This
note does not apply if you replace existing components with the same type
of component.
PTX1000 Port Panel on page 23
PTX1000 Network Port LEDs on page 29
96.
2—
Fan modules (3)
Copyright © 2018, Juniper Networks, Inc.