8.4.3.4 Set up LoggerNet

The LoggerNet Network Map is configured from the LoggerNet Setup screen.
NOTE:
Setup has two options, EZ (simplified) and Standard. Click on the View menu at the top of the
Setup screen, and select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure the Network Map as described in
the following steps:
 1. Select Add Root > IPPort.
 2. For PakBus data loggers select PakBusPort.
NOTE:
PakBus data loggers include the following models: GRANITE-series, CR6, CR3000,
CR1000X, CR800-series, CR300-series, CR1000, and CR200(X)-series.
 3. Add a data logger.
 4. Select the IPPort in the Network Map. Enter the CELL200 series IP address (public static IP),
along with the port number. The address and port number are input in the Internet IP
Address field separated by a colon. Preceding zeros are not entered (for example,
070.218.074.247 is entered as 70.218.74.247). For serial server mode, the default port
number is 3001.