8.4.3.1 Configure CELL200 series

To set up the CELL200 series in serial server mode:
1. Connect a USB cable between your module and computer.
2. Connect the cellular antenna, if it is not already connected. When using a MIMO antenna
with multiple cellular connections, connect the primary cable to Cellular and the secondary
to Diversity. If the cables are not marked in this way, they can be connected to either
antennna port. See
3. Open a web browser and go to:
TIP:
If this doesn't work browse to 192.168.86.1.
4. On the Settings > General tab, enter the APN provided by your cellular provider.
5. Set Mode to Serial Server.
6. On the Settings > Serial Mode Setup tab, set Serial Server Listen Port Number. Default is
3001. This is entered along with the IP address as part of the LoggerNet configuration.
7. When using a CR200(X), set RS-232 baud rate to 9600 baud.
Antenna
connections (p. 33).