Configure Data Logger - Campbell CELL200 Series Product Manual

4g lte cellular module
Hide thumbs Also See for CELL200 Series:
Table of Contents

Advertisement

 2. Connect your data logger RS-232 or CS I/O port to the CELL200-series module RS-232 or
CS I/O port. Ensure the same port is used for each device, for example RS-232 to RS-232.
See
Wiring and
 3. If not connecting through CS I/O, provide power to the CELL200 series. The data logger
provides power through the CS I/O port. USB power is not sufficient to power the CELL200
series; 12 V is required.

6.2.2 Configure data logger

 1. Connect to your data logger by using Device Configuration Utility.
 2. On the PPP tab, set Config/Port Used to CS I/O SDC8 or RS-232, depending on how you
are connected to the data logger.
 3. (Optional) On the PPP tab, set User Name and Password if required by your cellular carrier
(usually outside of the United Sates).
 4. Verify the Modem Dial String setting is blank.
 5. If connecting through RS-232, on the Comport Settings tab, set RS232 BaudRate to 115200
Fixed.
connections (p. 29).
CELL200-Series 4G LTE Cellular
Module     19