Available settings are explained as follows:
Item
ACS Settings
CPE Settings
Periodic Inform
Settings
STUN Settings
XMPP Settings
After finishing this web page configuration, please click OK to save the settings.
Description
TR-069 Enable - Select to enable TR-069 settings.
Wizard – Click it to enter the IP address of the VigorACS server host,
port number, and the handler.
URL/Username/Password – Such data must be typed according to
the ACS (Auto Configuration Server) you want to link. Please refer to
the Auto Configuration Server user's manual for detailed information.
Test With Inform – Click it to send a message based on the event
code selection to test if such CPE can communicate with the VigorACS
server.
Event Code – Use the drop-down menu to specify an event to
perform the test.
Last Inform Response Time – Display the time that the VigorACS
server made a response while receiving Inform message from CPE last
time.
Such information is useful for Auto Configuration Server (ACS).
SSL(HTTPS) Mode - Check the box to allow the CPE client to connect
with ACS through SSL.
On – Choose the interface (LAN-A or LAN-B) for VigorAP 906
connecting to the ACS server.
Port – Sometimes, port conflict might occur. To solve this problem,
you might change the port number for CPE.
Username/Password – Type the username and password that
VigorACS can use to access such CPE.
The default setting is Enable. Please set interval time or schedule time
for the AP to send a notification to the VigorACS server.
Interval Time – Type the value for the interval time setting. The unit is
"second".
The default is Disable.
If you click Enable, please type the relational settings listed below:
Server Address – Type the IP address of the STUN server.
Server Port – Type the port number of the STUN server.
Minimum Keep Alive Period – If STUN is enabled, the CPE must send
a binding request to the server to maintain the binding in the
Gateway. Please type a number as the minimum period. The default
setting is "60 seconds".
Maximum Keep Alive Period – If STUN is enabled, the CPE must send
a binding request to the server to maintain the binding in the
Gateway. Please type a number as the maximum period. A value of
"-1" indicates that no maximum period is specified.
XMPP is an abbreviation of Extensible Messaging and Presence
Protocol. If your AP register to XMPP server, it could help VigorACS to
manage the AP under the NAT at any time, without obstruction.