Refresh Time For Special Auxiliary Relays - Delta AS Series Programming Manual

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

SM
Error in data exchange connection 28 through
*SM1915
Function Card 2
Error in data exchange connection 29 through
*SM1916
Function Card 2
Error in data exchange connection 30 through
*SM1917
Function Card 2
Error in data exchange connection 31 through
*SM1918
Function Card 2
Error in data exchange connection 32 through
*SM1919
Function Card 2
*1: For items with a * mark, Refer to Section 2.2.1.6 for Additional Remarks on Special Auxiliary Relays and Special Data
Registers for details.
*2: The system executes according to the parameters set in HWCONFIG. When the SM power changes from OFF to
ON, the state is -, and the latched area is marked as N.
*3: The function card here means AS-F232, AS-F422 and AS-F485.

2.2.8 Refresh Time for Special Auxiliary Relays

Special auxiliary
relay
The system automatically sets the flag to ON and resets it to OFF.
SM0–SM1
ON: operation error.
The system automatically sets the flag to ON and resets it to OFF.
SM5
ON: an error occurs when the program is written in the PLC.
During power-on, the system checks whether the data in the latched area has been lost.
SM6
ON: data in the latched area has been lost. You reset it to OFF.
SM7
ON: power supply (24 V) is not sufficient. You reset it to OFF.
The system automatically sets SM8 to ON and resets it to OFF.
SM8
ON: there is a watchdog timer error.
The system automatically sets SM9 to ON and resets it to OFF.
SM9
ON: there is a system error.
The system automatically sets SM10 to ON and resets it to OFF.
SM10
ON: there is an I/O bus error.
You set the flag to ON, and the system automatically resets it to OFF.
SM22–SM24
ON: the log is cleared.
ON: users are editing with ISPSoft.
SM25–SM26
OFF: users have logged out of ISPSoft.
SM27
Update the value in the built-in AD for AS-F2AD. The system resets it to OFF.
The system checks for anything wrong.
SM28
ON: something is wrong. You reset it to OFF.
ON: an error occurs in the remote module. The system resets it to OFF.
SM30
ON: the wrong password is entered. The system resets it to OFF.
SM34
SM36
ON: the system saves the data to the memory card. After saving is complete, the system resets it
Function
OFF
STOP
RUN
STOP
ON
RUN
OFF
OFF
OFF
OFF
OFF
Refresh time
Cha p ter 2 De vices
N
R
OFF
N
R
OFF
N
R
OFF
N
R
OFF
N
R
OFF
2 - 6 5
2_