Troubleshooting
RF Output Power Problems
This executes the manual fixed power search routine, which is the default mode.
Setting the Power Search Reference (E8267D only)
NOTE
A successful power search is dependent on a valid power search reference.
Additionally, on the E8267D, there are up to four Power Search Reference modes: ARB RMS, Fixed,
Manual RMS or Manual, and Modulated. These four reference modes select the reference voltage used
while the RF signal is being I/Q modulated. (Power search reference modes are not used for analog
modulation: FM, PM, or pulse modulation.)
CAUTION
If the power search reference has the incorrect RMS voltage, the output power will be
incorrect. Refer to
Waveform Sample Point"
Waveform."
Figure 13-3
The Output Power Error
Where:
V1 is the actual waveform RMS voltage
V2 is the entered RMS voltage
Note: If the RMS voltage value entered is lower than the actual RMS voltage, the output power will be higher than desired.
If the RMS voltage value entered is higher than the actual RMS voltage, the output power will be lower than desired.
Figure 13-4
Because the RMS calculation, that is done by the signal generator, is
slow and may not be appropriate for your application, it is recommended
that the user calculate and enter in their measured RMS value for the
waveform file.
For a programming example of determining the RMS voltage of a waveform, refer to the Programming Guide and to the
Documentation CD that came with this instrument.
ARB RMS
During ARB RMS, the
is disabled, and the I/Q modulator is biased with a DC level that is equivalent to
the RMS voltage of the modulating signal. This selection is typically used with
internally generated baseband I/Q modulations. When the search is complete, the
284
Figure 13- 3, "Calculating the Output Power Error for a Single
and
Figure 13- 4, "Calculating the RMS Voltage of the
Calculating the Output Power Error for a Single Waveform Sample Point
×
(
=
20
log
10 V1
Calculating the RMS Voltage of the Waveform
RMS value for the waveform =
SCPI Commands:
[:SOURce]:RADio:ARB:HEADER:RMS <"file_name">,<val>|UNSPecified
[:SOURce]:RADio:ARB:HEADER:RMS? <"file_name">
Power Search Reference
(
)
(
)
)
V2
is set to ARB RMS, the I/Q modulation