Custom Real Time I/Q Baseband
Working with Differential Data Encoding
5. Press
>
Return
Differential Encoding Off On
This applies the custom differential encoding to a user–defined modulation.
NOTE
Notice that (UNSTORED) appears next to Differential State Map on the signal generator's
display. Differential state maps are associated with the user–defined modulation for which
they were created.
To save a custom differential state map, you must store the user–defined modulation for
which it was designed. Otherwise the symbol table offset data is purged when you press the
Confirm Exit From Table Without Saving
200
.
softkey when exiting from the I/Q or FSK editor.