Basic Digital Operation
Arbitrary (ARB) Waveform File Headers
Viewing Header Information with the Dual ARB Player Off
One of the differences between a modulation format and the dual ARB player is that even when the
dual ARB player is off, you can view a file header. You cannot, however, modify the displayed file
header unless the dual ARB player is on, and the displayed header is selected for playback. With the
dual ARB player off, perform the following steps.
1. Select a waveform:
a. Press
>
Mode
Dual ARB
b. Highlight the desired waveform file.
c. Press the
Select Waveform
2. Access the file header: Press
The header information is now visible in the PSG display. As shown in
editing softkeys are grayed–out, meaning they are inactive.
Figure 3-6
88
>
.
Select Waveform
softkey.
>
ARB Setup
Viewing Header Information
.
Header Utilities
Page 1
Page 2
Figure 3-
6, the header
Header editing softkeys
grayed–out
File header information and
current signal generator
settings
Note: When the dual ARB
player is off, the current
instrument settings column
does not update; the values
displayed may not be valid.