f. Use conductive field service tools.
g. When removing a FRU, immediately place it in anti-static packaging.
h. Avoid touching pins, leads, or circuitry.

Replace a 5U enclosure drive module in its carrier

The operator's (ops) panel registers either a logical fault or a drawer hardware fault or both. You must locate a faulty drive in
its carrier (DDIC) within the related drawer by its amber fault condition LED.
An important feature of the storage enclosure design is redundancy. The enclosure will maintain continuous operation during
the replacement of a single DDIC, if it is within the time limit of 7 minutes, since opening a drawer to remove a DDIC
significantly reduces airflow in the storage enclosure.
CAUTION If you remove any FRU while the storage enclosure is powered up, you must replace it with a tested, good
spare within the allotted time for that FRU. If you do not replace the FRU and, when applicable, fully close the related drawer
within the identified time limit, you void the product warranty and the storage enclosure might overheat, causing equipment
failure and possible data loss.
CAUTION Do not remove covers from any FRU. There is a danger of electric shock inside. Return the FRU to your
supplier for repair.
The steel carrier provides thermal conduction, radio frequency, electro-magnetic induction, and physical protection. For this
task, treat the drive carrier and its installed drive as a single FRU.
To replace a 5U enclosure drive module in its carrier:
1. Complete the following actions to open the related drawer:
a. Facing the front of the storage enclosure, determine which drawer has a fault condition by the fault LEDs on the ops
panel and drawer panels.
Color
State
On*
Fast flash (1s on, 1s off)
Amber
Slow flash* (3s on, 1s off)
Off

Figure 72 Drive fault LED on carrier bezel

Status
Drive has hardware fault, replace as soon as possible
Drive link down
Unit identification (UID) or locate is active for drive
Drive in critical condition
Failed array
No AC power present
Drive initialization in process
Drive quarantined
Chapter 11   In-service field maintenance for 5U  enclosures