4. Complete the following actions to insert the 2U chassis into the rack cabinet:
a. Facing the front of the enclosure, carefully exert even pressure on both sides of the storage enclosure front, inserting
the storage enclosure until the rack ear flanges are flush with the front rack posts.
b. Carefully lower the mechanical lift.
c. Thoroughly examine the rack rails for issues such as bowing, scraping, resistance, or indicators of misalignment.
5. Complete the following actions to secure the 2U chassis:
a. Facing the rear of the enclosure, insert and tighten a Panhead M5 x 8 screw into the tail of each outer rail and through
the 2U chassis to secure the rear of the chassis.
b. Facing the front of the 2U chassis, insert a Phillips-head screws with the hex head flanges into the operator's
(ops)  panel with an 8mm nut driver or a Philips screwdriver.
29            Chapter 4   Installation of 2U enclosures

Figure 13 Installation of 2U rear screw to secure chassis to rail

Figure 14 Installation of 2U operator's panel screw and cover