Interpret drawer LED panels

Each storage enclosure drawer bezel contains 2 LED panels to reflect drawer status and activity, 1 for each sideplane. Each
sideplane represents a data path within the drawer. You can monitor the drawer LED panels to determine drawer status in
combination with the user interface content.
In the case of a fault condition, identified in the state column with an asterisk (*), troubleshoot the fault. If a fault exists on a
single data path, only the related LED panel reports the fault, just as it would with a cable module, cable link, or drive faults.
Refer to the baseboard management controller (BMC) system event log (SEL) for detailed information.
Color
State
On
Green
Flashing (1s on, 1s off) SCSI enclosure services (SES) controlled UID or locate active
Green
On
Amber
On
None
Off
On*
Amber
Flashing*
Off
On*
Amber
Flashing*
Off
On*
Flashing (1s on, 1s off) UID or locate active for Drawer 1, Drawer 2 sideplane or drive
Amber
Off

Figure 41 5U84 operator's panel LEDs

Status
Unit identification (UID) of storage enclosure (0-99)
Storage enclosure power is on
Storage enclosure has AC power and is on standby as enclosure comes online
Storage enclosure AC power is off
Ops panel completing 5s test
Module fault in rear panel area, when paired with module fault LED
Drive fault, when paired with drive fault LED
Unknown, invalid, or mixed module types, such as mixed drive modules or PSUs
Vital product data (VPD) configuration error or 1²C bus fault
Storage enclosure rear panel area modules functioning properly
System component hardware fault:  drive, cable, or fanout card
System component hardware change of status
Drive fault caused loss of redundancy
System software reports an informational condition for the array, such as a
rebuild operation, with corresponding drives registering a fault
System component hardware functioning properly, no errors
Upper, lower drawer hardware fault: drive, cable, or fanout card
Upper, lower drawer hardware functioning properly