Interpret Controller Module Leds; Figure 42 5U84 Drawer Led Panel - Seagate Exos X 4006 Series Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos X 4006 Series:
Table of Contents

Advertisement

LED Type
Color
Power and
sideplane
Green
OK
Drawer
module
Amber
fault
Logical
Amber
status
Drawer
Amber
cable fault
Drawer data
Green
activity bar

Interpret controller module LEDs

There are two redundant controller modules (CMs) that use a series of LEDs to reflect host connectivity status. You can
monitor the LEDs from the rear panel area to determine system status in combination with the user interface content. You
cannot mix controller types when daisy-chaining controllers.
In the case of a fault condition, identified in the state column with an asterisk (*), troubleshoot the fault and take appropriate
corrective action.
59            Chapter 7   Operation of 5U enclosures
State
Status
Drawer power on and sideplane hardware functioning properly
On
Power to drawer off
Off
On*
Drawer module fault condition for drawer sideplane or drive
Flashing (1s on, 1s off)
Unit identification (UID) or locate active for drawer sideplane or drive
Off
Drawer modules functioning properly
On*
Drive hardware fault condition
Flashing* (3s on, 1s off)
One or more arrays impacted by drive hardware fault conditions
Off
Drive module hardware functioning properly
On*
Cable between rear panel area and drawer fault condition
Off
Cables functioning properly
Segments reflect amount of data activity: greater numbers of segments
Flashing (1s on, 1s off)
reflect greater data activity
Off
No data activity

Figure 42 5U84 drawer LED panel