Figure 64 Removal Of 2U12 And 2U24 Drive In Carrier - Seagate Exos X 4006 Series Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos X 4006 Series:
Table of Contents

Advertisement

To replace a 2U enclosure drive module in its carrier:
1. Complete the following actions to remove a faulty DDIC:
a. Facing the front of the storage enclosure, locate the DDIC with a fault condition.
b. Using a thumb and forefinger, squeeze the carrier release latch to release the connection to the midplane.
c. Grasping the carrier handle, pull it outward approximately 25mm (1 in) and wait for 30 seconds.
d. Use one hand to support the weight of the DDIC and the other to pull the handle outward to fully withdraw the DDIC.
e. Place it in a static-protected location.
2. Complete the following actions to replace it with a tested, good DDIC:

Figure 64 Removal of 2U12 and 2U24 drive in carrier