Preparing for Installation
Power Connection Guidelines for AC-Powered Routers
OL-13831-01
When the Cisco XR 12406 Router operates with an AC PDU, observe these
guidelines:
Original series Cisco XR 12406 routers: A power factor corrector (PFC)
allows the power supply to accept AC power source voltage from an AC
power source operating from 100 to 120 VAC 20-amp service in North
America, and a range of from 185 to 264 VAC 16-amp service in an
international environment.
Enhanced series Cisco XR 12406 routers: Supports 220 VAC only which
requires 20-amp service in North America, and 16-amp service in an
international environment.
Use only the 14-foot (4.3-meter) AC power cords shipped with the system.
Provide a dedicated power source with its own circuit breaker for each
AC-input power supply installed in the router.
Install an uninterruptable power source where possible.
Power plug types used in North America, Australia, and Europe are described in
Table 2-1
and shown in
Table 2-1
AC-Input Power Cord International Options
Label
United States
United States
North America
Australia, New Zealand
Europe, Argentina, Brazil
Italy
United Kingdom
Figure
2-3.
Description
110 VAC (original
Cisco XR 12000 series
routers)
220 VAC (enhanced
Cisco XR 12000 series
routers)
20A, 250 VAC
15A, 250 VAC
16A, 250 VAC
16A, 250 VAC
13A, 250 VAC (13A
replaceable fuse)
Cisco XR 12406 Router Installation Guide
Installation Site Requirements
Cisco Product Number
CAB-GSR6-US
CAB-GSR6-220V-US
CAB-GSR16-US=
CAB-GSR16-AU=
CAB-GSR16-EU=
CAB-GSR16-IT=
CAB-GSR16-UK=
2-15