Mitsubishi Electric MELSEC L Series User Manual page 136

Programmable controller
Hide thumbs Also See for MELSEC L Series:
Table of Contents

Advertisement

No.
Name
SD290
SD291
SD292
SD293
SD294
SD295
SD296
Device
SD297
assignment 1
SD298
SD299
SD300
SD301
SD302
SD303
SD304
Device
SD305
assignment 1
(Index register)
SD306
Device
assignment 1
SD307
SD308
Device
assignment 2
(Assignment
SD309
including the
number of
SD310
points set to the
extended data
register (D) and
SD311
extended link
register (W))
134
Downloaded from
ManualsNet.com
Meaning
Number of points
Stores the number of points assigned to X. The number of points is fixed to 8192.
assigned to X
Number of points
Stores the number of points assigned to Y. The number of points is fixed to 8192.
assigned to Y
Number of points
Stores the number of points assigned to M. The number of points is fixed to 0.
assigned to M
Number of points
Stores the number of points assigned to L. The number of points is fixed to 0.
assigned to L
Number of points
Stores the number of points assigned to B. The number of points is fixed to 0.
assigned to B
Number of points
Stores the number of points assigned to F. The number of points is fixed to 0.
assigned to F
Number of points
Stores the number of points assigned to SB. The number of points is fixed to 8192.
assigned to SB
Number of points
Stores the number of points assigned to V. The number of points is fixed to 0.
assigned to V
Number of points
Stores the number of points assigned to S. The number of points is fixed to 0.
assigned to S
Number of points
Stores the number of points assigned to T. The number of points is fixed to 0.
assigned to T
Number of points
Stores the number of points assigned to ST. The number of points is fixed to 0.
assigned to ST
Number of points
Stores the number of points assigned to C. The number of points is fixed to 0.
assigned to C
Number of points
Stores the number of points assigned to D. The number of points is fixed to 0.
assigned to D
Number of points
Stores the number of points assigned to W. The number of points is fixed to 8192.
assigned to W
Number of points
Stores the number of points assigned to SW. The number of points is fixed to 8192.
assigned to SW
16-bit
modification,
Stores the number of points assigned to Z. The number of points is fixed to 0.
number of points
assigned to Z
Number of points
Stores the number of points assigned to ZR (for extension). The number of points is fixed
assigned to ZR
to 0.
(for extension)
Number of points
assigned to D
Stores the number of points assigned to D (including the extended data register). The
(for internal and
number of points is fixed to 0.
extension)
Number of points
assigned to W
Stores the number of points assigned to W (including the extended link register). The
(for internal and
number of points is fixed to 8192.
extension)
search engine
Explanation
Set by
(Set timing)
S
(Initial)

Advertisement