Connection Example 6: Connecting to SYSMAC CP1H-X40DT-D/CP1L-@@@DT-@
3-phase 200/240 VAC 50/60 Hz
CP1H-X40DT-D
Output terminal block
CW0 (CIO 0100.00)
COM (for CIO 0100.00)
CCW0 (CIO 0100.01)
COM (for CIO 0100.01)
Origin search 0 (CIO 0101.02)
24-VDC input terminal (+)
24-VDC input terminal (−)
COM (CIO 0101.00 to 0101.03)
Input terminal block
Pulse 0 origin input signal (CIO 0001.03)
COM (CIO 0000)
Pulse 0 origin proximity input signal (CIO 0000.01)
Precautions
for Correct Use
NFB
R
S
T
R7A-CPB@S
2 kΩ
2 kΩ
24 VDC
X1
X1
24 VDC
XB
Incorrect signal wiring can cause damage to Units and the Servo Drive.
Leave unused signal lines open and do not wire them.
Do not share the power supply for brakes (24 VDC) with the 24-VDC power
supply for controls.
Recommended surge absorption diode: RU2 (Sanken Electric) or the
equivalent
Main circuit
power supply
Main circuit contactor
OFF
ON
X1
MC1
X1
R7D-BP@
Reactor
CN1
CNA
L1
L2
22
+CW
L3
23
−
CW
24
+CCW
P
−
25
B1
CCW
4
ECRST
CNB
Red
U
White
10
INP
V
Blue
W
14
GND
Green/
21
Z
Yellow
1
+24VIN
Encoder Cable
2
RUN
CN2
R88A-CRGB@C
13
0GND
9
/ALM
11
BKIR
FG
26
24 VDC
MC1
SUP
Surge suppressor
Servo error display
PL
MC1
Connect External Regeneration
Resistor when required.
@
R88M-G
Servomotor Power
Cable
@
R7A-CAB
S
M
E
Brake Cable
R88A-CAGA@B
XB
B
Appendix-6
App