Download Print this page

Omron SMARTSTEP 2 R88M-G Series User Manual page 259

Servomotors/servo drives
Hide thumbs Also See for SMARTSTEP 2 R88M-G Series:

Advertisement

Alarm Codes and Meanings
Alarm
codes
11
Power supply undervoltage
12
Overvoltage
14
Overcurrent
15
Built-in resistor overheat
16
Overload
18
Regeneration overload
21
Encoder disconnection detection
23
Encoder data error
24
Deviation counter overflow
26
Overspeed
27
Electronic gear setting error
Note The following alarms are not recorded in the history.
11: Power supply undervoltage
36: Parameter error
37: Parameter corruption
38: Drive prohibit input error
95: Servomotor non-conformity
96:
LSI setting error
 Software Version
a.-k1k .0k7k
 Displays the software version of the Servo Drive.
 Warning Display
rknk-k-k-k- -
 Regeneration Load Ratio
rkgk k8k0.0
 Displays the load ratio as a percentage of the detection level for the regeneration load.
Meaning
a
: No warning,
: Warning
Overload: 85% or more of the alarm level for
overload.
Over-regeneration: 85% or more of the alarm level for
regeneration overload.
The alarm level will be 10% of the operating ratio of the
regeneration resistance if the Regeneration Resistance
Selection (Pn6C) is set to 1.
Not used.
Not used.
6-3 Using the Parameter Unit
Alarm
Meaning
codes
29
Deviation counter overflow
34
Overrun limit error
36
Parameter error
37
Parameter corruption
38
Drive prohibit input error
48
Encoder phase Z error
49
Encoder CS signal error
95
Servomotor non-conformity
96
LSI setting error
Others
Other errors
6
6-12

Advertisement

loading

This manual is also suitable for:

Smartstep 2 r7d-bp seriesSmartstep 2 r7d-bpa5lSmartstep 2 r7d-bp01Smartstep 2 r7d-bp02lSmartstep 2 r7d-bp01hSmartstep 2 r7d-bp04h ... Show all