Download Print this page

Omron SMARTSTEP 2 R88M-G Series User Manual page 183

Servomotors/servo drives
Hide thumbs Also See for SMARTSTEP 2 R88M-G Series:

Advertisement

Wiring Method
Connect the External Regeneration Resistor between terminals P and B1.
CNA
5
P
Servo Drive
3
B1
Precautions
for Correct Use
Combining External Regeneration Resistors
Regeneration ab-
*1
sorption capacity
R88A-RR08050S
Model
R88A-RR080100S
*2
Resistance
50 Ω/100 Ω
Connection
method
*1. Select a combination that has an absorption capacity greater than the average regeneration power (Pr).
*2. Do not use a combination of resistors with a resistance lower than the minimum external regenerative
resistance of each Servo Drive. For information on the minimum external regenerative resistance, refer to
Servo Drive Regenerative Energy Absorption Capacity on page 4-37.
θ>
Thermal Switch Output
External
Regeneration
Resistor
 Connect the thermal switch output so that the power supply is shut OFF
when the contacts open. Configure a sequence to shut OFF the power via
the thermal output. Not doing so may cause the resistor to overheat,
resulting in a fire or damage to the equipment.
20 W
40 W
R88A-RR08050S
R88A-RR080100S
25 Ω/50 Ω
R
R
R
4-4 Regenerative Energy Absorption
70 W
R88A-RR22047S
47 Ω
R
140 W
R88A-RR22047S
94 Ω
R
R
4-38