5-10 User Parameters
Pn42
Setting range
Set the input format of the pulse inputs sent as commands to the Servo Drive from the position
controller.
Explanation of Setting
Setting
0 or 2
5
Pn43
Pn44
Setting range
Set the number of encoder pulses to be output from the Servo Drive for each rotation.
The setting can be made from 1 to 16,384 pulses, but the setting will not be valid if it exceeds 2,500
pulses. (Any setting that exceeds the encoder resolution will be invalid.)
Even if the dividing rate is changed, there will always be 1 pulse per rotation for phase Z.
5-49
Command Pulse Mode
0 to 3
Unit
Command pulse mode
90° phase difference
(phases A and B)
signal inputs
Forward pulse and
reverse pulse inputs
1
Feed pulse input and
forward/reverse signal
3
Not used. (Do not change setting.)
Encoder Dividing Rate Setting
1 to 16384
Unit
---
Default setting
Servomotor forward command
t1
t1
Phase A
Phase B
t1
t1
Line driver: t1 ≥ 2 μs
Open collector: t1 ≥ 5 μs
Low
t2 t2
Line driver: t2 ≥ 1 μs
Open collector: t2 ≥ 2.5 μs
t2
t2
High
t2
Line driver: t2 ≥ 1 μs
Open collector: t2 ≥ 2.5 μs
Pulse
Default setting
1
Power OFF → ON
Servomotor reverse command
t1
t1
t1
t1
t2
t2
t2
Low
t2
t2
Low
t2 t2
t2
All modes
2500
Power OFF → ON
Position
Yes
Yes