Setting A Compensation Value For The Measurement Value - Omron K3HB-P User Manual

Digital indicators
Hide thumbs Also See for K3HB-P:
Table of Contents

Advertisement

5.21 Setting a Compensation Value for the Measurement
Value
Explanation of Functions
Compensation Conditions: None
Measurement value
Compensation
1
compn
L
(COMPN)
1
com-p
L
(COM-P)

5.21 Setting a Compensation Value for the Measurement Value

This function sets the measurement value to the compensation value
on the rising edge of the COMPENSATION input signal.
Compensation can be made conditional by selecting a compensation
condition.
Compensation, Compensation Conditions
By detecting the COMPENSATION rising edges, the measurement
value can be set to the preset compensation value. Compensation of
the measurement value can be specified to be performed only when
the immediately preceding input is an incremental input by setting the
compensation condition.
Input
compensation
value
Compensation performed regardless
of whether the immediately preceding
input is positive or negative.
Use the following parameter to set the compensation value.
Parameter
Compensation value
compn
Use the following parameter to set the compensation condition.
Parameter
Compensation
condition
com-p
Input adjustment level
Compensation Conditions: Plus
Measurement value
The immediately
preceding input is
positive, so
Input
compensation is
compensation
performed.
value
Compensation
Set value
Meaning of set value
−19999 to 99999
:9999 to
99999
Set value
Meaning of set value
none
No conditions
plus
Enabled only when the
immediately preceding
input is an addition.
C
The immediately
preceding input is
negative, so
compensation is not
performed.
5-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb-rK3hb-cK35-2

Table of Contents