Setting The Function For The K3Hb-P - Omron K3HB-P User Manual

Digital indicators
Hide thumbs Also See for K3HB-P:
Table of Contents

Advertisement

Section 5 Functions and Operations

5.2 Setting the Function for the K3HB-P

The K3HB-P supports six different measurement operations.
Explanation of Functions
■ F1: Passing Speed
Input A
Input B
Hold
Measurement value No measurement
5-16
Function
Measuring Workpiece Passing Speed between A and B
Operation Configuration (Application)
• Basic Operation
The reciprocal of the time T (s) from the turning ON of input A to
the turning ON of input B is multiplied by 60 and the workpiece
passing speed between points A and B is displayed.
1
× 60 × α
D =
T
T: Time (s) from the rising edge of input A to the rising edge of
input B
α: Prescale value A
D: Passing speed
Not valid
T
T
T
1
R
2
× 60 × α
1/T
1
*TR: Recovery Time
The time required from the end of one measurement until completing
preparations for the next measurement. Allow at least 1 ms.
A
B
Not valid
T
T
3
4
× 60 × α
1/T
1/T
2
Initial setting level
P
× 60 × α
4