5.33 Initializing All Settings

Important *
f
init
L
(INIT)
0
L
Displays "L 0."
amov
0
L
0
amov
0
L
00000
init
f
L
off
Displays "L f."
init
f
L
off
init
f
L
on
pass
f
L
pass
0
L
123. 4
123. 4
* If this operation is performed, all parameters return to the initial settings and current settings are
lost. It is recommended that before performing this operation, the Parameter List at the end of this
manual or some other method is used to record the current set values.
Initialization can be used to start settings over again from the default
settings. Refer to "Parameter List" (P.A-8) for information on default set
values.
Parameter Setting Procedure
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the M [MODE] Key several times to change the PV display
M
to "amov."
• This parameter is not displayed for the initial status due to setting
level protect.
Refer to "5.34 Limiting Key Operations" (P.5-84) for information on
removing setting level protect.
C Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
D Use the U [UP] and S [SHIFT] Keys to set the password
U
"-0169." Press the M [MODE] Key to move to the advanced function
setting level.
M
f" is displayed on the level/bank display to indicate the
• "
L
advanced function setting level.
E Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
F Use the U [UP] Key to change the SV display to "on."
U
G Press the M [MODE] Key to switch to the next parameter and
M
execute initialization.
• The set value is registered.
H Press the L [LEVEL] Key for at least 1 s to return to the initial
L
setting level.
1 s min.
I Press the L [LEVEL] Key for at least 1 s to return to RUN level.
L
1 s min.
5.33 Initializing All Settings
Advanced function setting level
R
P C
5-83

Advertisement