5.17 Reversing Output Logic

f
out-n
L
(OUT-N)
0
L
Displays "L 0."
amov
0
L
0
amov
0
L
00000
init
f
L
off
Displays "L f."
out-n
f
L
n-o
out-n
f
L
n-o
The output logic reversal function sets the logic of comparative outputs
for comparative results.
Parameter
Output
logic
out-n
The comparative outputs will turn OFF if an input error occurs when
"open in alarm" is set.
Parameter Setting Procedure]
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the M [MODE] Key several times to change the PV display
M
to "amov."
• This parameter is not displayed for the initial status due to
setting level protect.
Refer to "5.34 Limiting Key Operations" (P.5-84) for information
on removing setting level protect.
C Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
D Use the U [UP] and S [SHIFT] Keys to set the password "-
U
0169." Press the M [MODE] Key to move to the advanced
function setting level.
M
f" is displayed on the level/bank display to indicate the
• "
L
advanced function setting level.
E Press the M [MODE] Key several times to change the PV display
M
to "out-n."
F Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
5.17 Reversing Output Logic
Set
Comparative
Comparative
value
result
output status
Close
ON
in
OFF
alarm
n-o
Open
ON
in
OFF
alarm
n-c
Advanced function setting level
R
P C
Operation
Comparative
output
ON
ON
OFF
OFF
ON
OFF
OFF
ON
5-53