Setting Mode

3-2-2 Menu Overview

RUN Mode
Refer to Section 4 RUN Mode Operations.
Setting Mode
Output test
Refer to Section 5
Useful Functions.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
22
Press the Mode and Shift Keys
while turning the K3NX on.
Power On
Press the Mode
Key for 1 second.
Press the
Escape Key.
Setting value menu
Press the Mode Key for 1 second.
(see note 1)
HH setting value
–19999 to 99999
H setting value
Note 1:
When making new settings
or changing settings of each
L setting value
parameter, press the Shift
Key to shift to the setting
state.
The input will be updated
LL setting value
automatically if no change is
made for five seconds.
Option menu
Press the Mode Key for 1 second.
Average processing
Startup compensa-
tion time
Hysteresis
Comparative output
pattern
H linear output
range
L linear output
range
Remote/Local pro-
cessing
Maintenance Mode
Refer to Section 5 Useful Functions.
Press the Escape Key.
Press the Escape and
Protect Mode
Up Keys for 1 second.
Refer 3-3 Protect Mode.
Press the
Escape Key.
Setup Menu
Input range
Power supply
frequency
Communications
unit number
Baud rate
Word length
Stop bits
Parity bits
Section 3-2
Scaling menu
Press the Mode Key for 1 second.
Input value 2
Display value 2
Input value 1
Display value 1
Decimal position
Press the Mode Key for 1 second.
Note 2:
The K3NX stops measurement
in setting mode.
Some menus cannot be set ac-
cording to the Output Board se-
lected.
If the input range is changed, all
the other parameters are set to
default values. Therefore, set
the input range first.