Parameter reference
Response Rate (2.3.8.1.)
*
Use a setting just faster than the maximum filling or emptying rate (whichever is faster).
Fill Rate per Minute (2.3.8.2.)
Defines the maximum rate at which the reported sensor value is allowed to decrease. Allows
you to adjust the SITRANS LR250 response to decreases in the actual material level. Fill Rate is
automatically updated whenever Response Rate (2.3.8.1.) is altered.
Sensor value is the value produced by the echo processing which represents the distance
from sensor reference point to the target [see Low Calibration Point (2.3.7.1.) for an
illustration].
Options
Altered by:
Related parameters
Enter a value slightly greater than the maximum vessel-filling rate, in units per minute.
Empty Rate per Minute (2.3.8.3)
Defines the maximum rate at which the reported sensor value is allowed to increase. Adjusts
the SITRANS LR250 response to increases in the actual material level. Empty Rate is
automatically updated whenever Response Rate is altered.
The sensor value is the value produced by the echo processing which represents the distance
from sensor reference point to the target [see Low Calibration Point (2.3.7.1.) for an
illustration].
Options
Altered by:
Related parameters
Enter a value slightly greater than the vessel's maximum emptying rate, in units per minute.
126
Fill Rate per Minute (2.3.8.2.)/
Empty rate per Minute (2.3.8.3.)
Slow
Medium
Fast
Range: 0 to 999999 m / min.
Response Rate (2.3.8.1.)
*
Slow
Medium
Fast
Response Rate (2.3.8.1.)
Level Unit (2.3.2.)
Range: 0 to 99999 m / min.
Response Rate (2.3.8.1.)
*
Slow
Medium
Fast
Response Rate (2.3.8.1)
Level Unit (2.3.2.)
0.1 m/min (0.32 ft/min)
1.0 m/min (3.28 ft/min)
10.0 m/min (32.8 ft/min)
Fill Rate per Minute (2.3.8.2.)
0.1 m/min (0.32 ft/min)
1.0 m/min (3.28 ft/min)
10.0 m/min (32.8 ft/min)
Empty Rate
0.1 m/min (0.32 ft/min)
1.0 m/min (3.28 ft/min)
10.0 m/min (32.8 ft/min)
SITRANS LR250 with FOUNDATION FIELDBUS
Operating Instructions, 09/2021, A5E32221411-AH
Shots (2.5.6.)
25
10
5