Ricoh Aficio 2035e Service Manual page 223

Hide thumbs Also See for Aficio 2035e:
Table of Contents

Advertisement

1105*
Fusing Temperature Adjustment
Allows adjustment of the hot roller temperature at the center and ends of the roller
for the quality or thickness of the paper. The hot roller in this machine has two
fusing lamps: one heats the center of the roller, the other heats both ends. Each
fusing lamp can be adjusted separately.
The "re-load temperature" is the "print ready temperature. When the fusing
temperature exceeds this setting, the machine can operate. Do not set up a re-
load temperature (Re-load Temp. = Fusing. Temp – SP Value.) that is higher
than the SP1-105-2 setting.
1105 1
Roller Center: Trays
Adjusts the fusing temperature at the center of the hot roller.
1105 2
Roller Ends: Trays
Adjusts the fusing temperature at the ends of the hot roller.
1105 3
Roller Center – Bypass
Adjusts the fusing temperature at the center of the hot roller for bypass feed.
1105 4
Roller Center - Ends
Adjusts the fusing temperature at the ends of the hot roller for bypass feed.
1105 5
Re-load Temp. Minus:
Roller Center
Sets the temperature for re-heating the hot roller center.
1105 6
Re-load Temp. Minus:
Roller Ends
Sets the temperature for re-heating the hot roller ends.
1105 7
Roller Center: Bypass
(Thick Paper)
Adjusts the fusing temperature at the center of the hot roller for thick paper.
1105 8
Roller Ends: Bypass (Thick
Paper)
Adjusts the fusing temperature at the ends of the hot roller for thick paper.
1105 9*
Re-load Temp. Minus:
Roller Center (Thick Paper)
Sets the temperature for re-heating the hot roller center for thick paper.
1105 10*
Re-load Temp. Minus:
Roller Ends (Thick Paper)
Sets the temperature for re-heating the hot roller ends for thick paper.
SM
SERVICE PROGRAM MODE
35 cpm: [120 ~ 200/ 150 / 1 deg.]
45 cpm: [120 ~ 200 / 170 / 1 deg.]
35 cpm: [120 ~ 200 / 160 / 1 deg.]
45 cpm: [120 ~ 200 / 175 / 1 deg.]
35 cpm: [120 ~ 200 / 160 / 1 deg.]
45 cpm: [120 ~ 200 / 170 / 1 deg.]
35 cpm: [120 ~ 200 / 160 / 1 deg.]
45 cpm: : [120 ~ 200 / 170 / 1 deg]
[0 ~ 60 / 30 / 1 step]
[0 ~ 60 / 30 / 1 step]
35 cpm: [120 ~ 200 / 170 / 1 deg]
45 cpm: [120 ~ 200 / 170 / 1 deg]
35 cpm: [120 ~ 200 / 170 / 1 deg]
45 cpm: [120 ~ 200 / 170 / 1 deg]
o
35 cpm: [0 ~ 60 / 0
C/ 5]
o
45 cpm: [0~ 60 / 5
C /1]
o
35 cpm: [0 ~ 60 / 0
C/ 5]
o
45 cpm: [0~ 60 / 5
C /1]
5-7
B135/B138

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aficio 2045eB135B138

Table of Contents