LOCATION OF UNIT

Locate the dispenser so that the following requirements are satisfied:
1. Unit is not to be installed in an area where a water jet (power washer) is used.
2. Unit must be located in an area with a level floor surface. The unit must be installed within 2° of level for
the unit to operate properly.
3. The unit should only be installed in a location where its use and maintenance is restricted to trained per-
sonnel.
4. Unit must be located in an area with nearest access to floor drain port, preferably under the foot print of
unit.
5. The clearance above top of the unit must be open and the front of the unit must be open to the room.
These clearances must be provided to allow for proper air flow and to allow access to the ice bin for refill-
ing.

POWER ON UNIT

!
DANGER:
To avoid possible fatal electrical shock or serious injury to the operator, it is highly recommended that a GFI
(ground fault circuit interrupter) be installed in the electrical power circuit.
The machine is equipped with a power cord (hot, neutral and ground) and is plugged into any standard wall outlet
capable of handling 15 A at 120VAC, 60Hz volts as shown in Table 3 on page 6.
Unit
ABS 2.0
!
CAUTION:
The electrical circuits must be properly fused (Slow-blow type fuses). Do not use HACR circuit breakers on the
circuit of the unit. HACR circuit breakers may not react to voltage surges or spikes that can damage the
electronics
NOTE: The electrical outlets must be accessible for ease of connecting and disconnecting the
dispenser cords. No other electrical appliances should be connected to these electrical
circuits.
NOTE: All electrical wiring must conform to national and local electrical codes.
Publication Number: 621058590OPR

NORMAL OPERATIONS

O
U
& U
N
NIT
SAGE
Table 3.Product electrical requirement
Plug Type
IEC-NEMA 5-15P
Voltage-Frequency-Phase
120 VAC – 60 Hz – 1Ph
- 6 -