Normal Operations; Location, Power On Unit & Usage; Location Of Unit; Power On Unit - Cornelius ABS 2.0 Operator's Manual

Hide thumbs Also See for ABS 2.0:
Table of Contents

Advertisement

L
, P
OCATION
OWER

Location Of Unit

Locate the dispenser so that the following requirements are satisfied:
1. Unit is not to be installed in an area where a water jet (power washer) is used.
2. Unit must be located in an area with a level floor surface. The unit must be installed within 2° of level for
the unit to operate properly.
3. The unit should only be installed in a location where its use and maintenance is restricted to trained per-
sonnel.
4. Unit must be located in an area with nearest access to floor drain port, preferably under the foot print of
unit.
5. The clearance above top of the unit must be open and the front of the unit must be open to the room.
These clearances must be provided to allow for proper air flow and to allow access to the ice bin for refill-
ing.

Power On Unit

!
DANGER:
T
o avoid possible fatal electrical shock or serious injury to the operator, it is highly recommended that a
(ground fault circuit interrupter) be installed in the electrical power circuit.
The machine is equipped with a power cord (hot, neutral and ground) and is plugged into any standard wall
outlet capable of handling as shown in Table 3 on page 7.
Unit
Plug Type
ABS 2.0
IEC-NEMA 5-15P
ABS 2.0
CEE7/7
ABS 2.0
BS1363A
ABS 2.0
AS3112
!
CAUTION:
T
he electrical circuits must be properly fused (Slow-blow type fuses).
breakers on the circuit of the unit.
damage the electronics
NOTE: The electrical outlets must be accessible for ease of connecting and disconnecting the
dispenser cords. No other electrical appliances should be connected to these electrical
circuits.
NOTE: All electrical wiring must conform to national and local electrical codes.
© 2019, Cornelius Inc.

NORMAL OPERATIONS

O
U
& U
N
NIT
SAGE
Table 3.Product electrical requirement
Region
North America's
European CENELEC Member
Countries
Great Britain/Ireland
Australia
HACR
circuit breakers may not react to voltage surges or spikes that can
Voltage-Frequency-Phase
120 VAC – 60 Hz – 1Ph
220-240 V, 50-60 Hz – 1Ph
220-240 V, 50-60 Hz – 1Ph
220-240 V, 50-60 Hz – 1Ph
DO NOT
- 7 -
ABS 2.0 Operator's Manual
GFI
Amps
15
10
13
10
HACR
use
circuit
Publication Number: 621058590OPR