Diagnosis and service scans
Service functions
The following service functions can be selected:
Service function
"Diagnosis"
"Actuator test"
"Code 1"
"Code 2"
"Fault history"
"Service functions"
*6
"Maintenance"
■
"Calibrate O2 probe"
■
"Fill vacuum module"
■
"Run pellet hopper until emp-
■
ty"
"Changeover unit"
■
"Standard setting"
■
"Terminate service"
Calling up the service menu
The service menu can be activated from any menu.
Press the following keys:
1.
+
Simultaneously for approx. 4 seconds.
d
å
The "Service" menu appears.
Exiting the service menu
You can leave the service menu as follows:
Depending on system configuration, other displays will be available.
*6
120
See page
Function
121
Checking operating states, actuators and sensors
121
Checking the actuators
100
Configuring the system
113
Configuring the system
127
Calling up fault codes from the fault memory
75
Maintenance status
■
Hours run/days remaining until next maintenance
Overview
■
Display of last 5 services
Maintenance reset
■
Confirmation of commissioning or maintenance carried
out
Hours run
■
Maintenance interval
Setting for hours run until next service
136
Calibrating the O
(calibrating the Lambda probe)
123
Vacuum module
Filling the pellet hopper
■
Checking
■
123
Setting the interval for running the pellet hopper until empty
124
Checking the changeover unit
125
Loading the standard setting:
All data
■
General
■
Boiler
■
Charging
■
Buffer
■
Additional boiler
■
All groups
■
120
Exiting the service menu
2.
|
■
By pressing
■
Automatically after 30 min
Via menu point "Terminate service"
■
probe.
2
/
For the required service function.
~
ä