60 Installation and configuration
4
Installing the LMX
Configure the NT5D65 LMX DIP switches for the appropriate card address
(see
3 (SW3) is reserved and all positions should be OFF.
CAUTION
For proper operation of the Mini-Carrier
equipment, the following settings should be
verified:
Unused carrier links should be configured as "unequipped"
(using the set configuration command from the Man Machine
interface terminal), to avoid a constant alarm condition. The
alarm relay contacts will remain active during such an alarm
condition.
Install the local MMI terminal and T1 carrier link cables to the
LMI Multi I/O cable assembly. See
single Local Mini-carrier Interface card (LMI)" (page 41)
illustration of the cable connections necessary for a single LMI
system. For an illustration of the cable connections necessary to
daisy chain the LMI's terminal connection, see
Local Mini-carrier Interface cards (LMIs) in a daisy chain" (page
42).
a For single-LMI systems, SW2 positions 7 and 8 are OFF. See
Table 9 "LMI SW2 at U23 functions" (page
b For daisy-chained systems, the LMI connected to the terminal
should have SW2 position 7 OFF and SW2 position 8 ON.
The LMI connected to the SDI port should have SW2 position
8 OFF and SW2 position 7 ON. The LMIs in the middle of
the daisy chain, those not on the MMI end or the SDI end,
should have SW2, positions 7 and 8 ON. See
SDI end" (page 56)
(page 57)
for brief instructions on how to properly set DIP
switches for daisy chaining.
Table 14 "LMX DIP SW2 function: LMX address" (page
Nortel Communication Server 1000
Mini-Carrier Remote Fundamentals
NN43001-557 04.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
Line build-out switches are set to
accommodate a cable length that
corresponds to the approximate length
to the CSU
CSU is configured for the same framing
format as the MCR (D4 or ESF)
CSU is NOT configured for robbed-bit
signaling
CSU accepts B8ZS zero-substitution codes
Figure 8 "Cabling for a
and
Table 10 "LMI SW3 at U51 functions"
--End--
for an
Figure 9 "Cabling
56).
"MMI end and
61)). Switch