Nortel Communication Server 1000 Fundamentals page 55

Mini-carrier remote fundamentals
Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

Local site installation
Install and verify the operation of the local system, if not already
installed and operating correctly.
Identify the line card slots and install the LMI and LMXs in the system.
(The LMI and LMXs must all be in the same IPE shelf or cabinet.)
Install the LMI/LMX cable.
Connect the LMI Multi-I/O cable assembly (NT5D85) to the SDI and
MMI ports, and the T1 carrier links.
Installing the LMI
The LMI can be installed when the system is powered up and running.
Table 12 "LMI standard (default) switch settings" (page
default (factory provided) switch settings on the LMI. Verify the switch
settings before installation.
Figure 11
Jumper settings on MCR circuit packs.
WARNING
DO NOT ALTER JUMPER SETTINGS!
The jumpers at J3 determine board type and should never be
removed or changed. Refer to
MCR circuit packs." (page 55)
jumpers.
Nortel Communication Server 1000
Mini-Carrier Remote Fundamentals
NN43001-557 04.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
System installation 55
58), lists the
Figure 11 "Jumper settings on
for the proper settings for these

Advertisement

Table of Contents
loading

Table of Contents