Nortel Communication Server 1000 Fundamentals page 49

Mini-carrier remote fundamentals
Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

"Mini-Carrier Remote-unique hardware list" (page 51)
component part numbers and descriptions.
Configure the NT5D64 (NT5D68 for cabinet systems) LMI DIP switches
to set the appropriate card address and other parameters. For help,
refer to:
Table 9 "LMI SW2 at U23 functions" (page 56)
Table 10 "LMI SW3 at U51 functions" (page 57)
Table 12 "LMI standard (default) switch settings" (page
Install the LMI into two adjacent line card slots.
Connect the NT5D85 LMI Multi I/O cable to the 50-pin Amphenol
connector for the first of the two line card slots occupied by the LMI.
Connect Plug 1 of the NT5D86 LMI/LMX cable assembly to the 50-pin
Amphenol connector for the second of the two line card slots occupied
by the LMI.
Install the local MMI terminal, and mini-carrier link cables to the LMI
Multi I/O cable assembly.
Configure the NT5D65 (NT5D69) LMX DIP switches to set the
appropriate card address. For help, refer to
function: LMX address" (page
Install the LMX(s) into two consecutive line card slots in the same IPE
shelf (or cabinet) as the LMI.
Connect Plug 2 of the NT5D86 LMI/LMX cable assembly to the 50-pin
Amphenol connector for the second of the two line card slots occupied
by LMX 1. (The 50-pin Amphenol connector for the first of the two line
card slots is not used.)
Connect Plug 3 of the NT5D86 LMI/LMX cable assembly to the 50-pin
Amphenol connector for the second of the two line card slots occupied
by LMX 2. (The 50-pin Amphenol connector for the first of the two line
card slots is not used.)
Connect Plug 4 of the NT5D86 LMI/LMX cable assembly to the 50-pin
Amphenol connector for the second of the two line card slots occupied
by LMX 3. (The 50-pin Amphenol connector for the first of the two line
card slots is not used.)
Remote site
Take inventory of MCR equipment by comparing the received
equipment against the shipping documents. Refer to
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
61).
Nortel Communication Server 1000
Mini-Carrier Remote Fundamentals
NN43001-557 04.01 4 June 2010
Quick reference to system installation 49
for MCR
( U23),
( U51), and
Table 14 "LMX DIP SW2
Table 8
58).

Advertisement

Table of Contents
loading

Table of Contents