Plar Mode Application; Figure 5-6. Daisy-Chaining Application - ADTRAN Express 5210 User Manual

Frame relay service unit
Table of Contents

Advertisement

Chapter 5. Applications

PLAR Mode Application

PLAR (private line automatic ringdown) mode connects up to two
remote telephone sets to one or two local telephone sets without a
PBX. PLAR mode runs over a point-to-point DDS network or over
a frame relay network. This mode requires the use of FXS modules
on both ends for connection to the telephone sets. In PLAR mode,
taking a phone off-hook rings the opposite end of the circuit. See
Figure 5-7.
For PLAR mode, the DLCI for each voice port must be pro-
grammed. In the case of a frame relay circuit, this is the local DLCI
that the voice data is to be carried on. For a point-to-point DDS cir-
cuit, the DLCI value must be non-zero and it must be the same on
both ends of the circuit.
5-12

Figure 5-6. Daisy-Chaining Application

Express 5210 User Manual
61200208L1-1