IP Address
Enter the IP address of the unit the Express 5210 is sending an echo
request (ping) to.
If the IP address is not manually configured into the IP route table, the
path will be determined dynamically through RIP and inverse ARP
protocols.
Count
Enter the number of pings to be sent (1 to 99).
Size <bytes>
Enter the number of data bytes to send with each ping.
Timeout <ms>
Enter the maximum time to wait for a ping response.
Round Trip Min
This field shows the shortest round-trip delay of the received
responses. Round-trip delay is counted from the time the ping is
sent until the response is received.
Round Trip Avg
This field shows the average response time based on all received
responses.
Round Trip Max
This field shows the longest round-trip delay of the received
responses. If a response is not received before the unit times out,
the delay is not calculated in.
Tx Stats
Results are shown as the ping test is being performed. The S
command causes the Express 5210 to send ping requests to the
target station. As the test progresses, the following results are
shown:
TXed
RXed
Lost
61200208L1-1
This field shows the number of pings sent.
This field shows the number of responses received
from the pinged device.
This field shows the number of ping requests sent that
were not responded to.
Express 5210 User Manual