12.5

Slimline ODD and LSD in Multibay box

12.5.1 Installing the slimline ODD or LSD

Upgrade and Repair Unit
(URU)
Tools: – Phillips PH2 / (+) No. 2 screw driver
– Slotted screw driver (for bending in or out accessible drive
mounting brackets)

12.5.1.1 Preliminary steps

"Shutting down the server" on page 50
Ê
"Disconnecting the server from the mains" on page 50
Ê
"Getting access to the component" on page 51
Ê
I
The front cover only needs to be removed in order to remove or install
accessible drive dummy covers. If the Multibay box is already
installed in the server and will be removed in order to install a slimline
ODD or LSD module, the front cover can remain installed.
"Removing the system fan holder" on page 76
Ê
"Removing the Multibay box" on page 296
Ê

12.5.1.2 Installing the slimline ODD

Ê Press up on the locking tab to disengage the slimline ODD dummy module
as shown in
figure 212 on page
Ê From inside the Multibay module, press out on the ODD dummy module and
pull it out of its bay.
TX150 S8 / TX200 S7
297.
Upgrade and Maintenance Manual
Accessible drives and LSD
Hardware: 10 minutes
(if applicable)
289