Setting method [A]

The encoder output pulse function can be used by setting the following servo parameters. For output specifications of the Z-
phase pulse, refer to the following.
Page 286 Z-phase pulse output
Servo
Symbol
parameter
PA15
*ENR
PA16
*ENR2
PC19.0
*ENRS
PC19.1
*ENRS
*1
PC19.2
*ENRS
*1 Available on servo amplifiers with firmware version A5 or later.
Name
Encoder output pulses
Encoder output pulses 2
Encoder output pulse - Phase
selection
Encoder output pulse setting
selection
Encoder selection for encoder
output pulse
Outline
Set the encoder output from the servo amplifier by using the number of output pulses
per revolution, dividing ratio, or electronic gear ratio. (after multiplication by 4)
The setting value varies depending on [Pr. PC19.1 Encoder output pulse setting
selection].
Initial value: 4000 [pulse/rev]
Set a denominator for the electronic gear when selecting "3" (A-phase/B-phase pulse
electronic gear setting) in [Pr. PC19.1 Encoder output pulse setting selection]. This is
not used for other settings.
Initial value: 1
Set the phase for the A-pulse and the B-pulse.
0: Increasing A-phase 90° in CCW or positive direction (initial value)
1: Increasing A-phase 90° in CW or negative direction
Select the method for setting the number of output pulses.
0: Output pulse setting (initial value)
1: Dividing ratio setting
2: The same output pulse setting as the command pulse
3: A-phase/B-phase pulse electronic gear setting
4: A/B-phase pulse through output setting
Select a servo motor encoder or load-side encoder for the encoder to output pulses.
Initial value: 0 (servo motor encoder)
4.13 A/B/Z-phase pulse output function
4 APPLICABLE FUNCTIONS
4