How To Use The Function [A] - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

How to use the function [A]

The automatic setting mode is enabled for the drive recorder function in the factory settings. If the initial
setting does not meet your needs, set [Pr. PA23 Drive recorder desired alarm trigger setting] and collect data
suitable for analyzing the occurrence factors of alarms. If satisfactory data cannot be obtained, use the
manual setting mode to collect the necessary data.
When an alarm occurs, data of the generated alarm is recorded inside the servo amplifier. By reading the recorded data, the
cause of the alarm can be analyzed.
Refer to the following for using the manual setting mode to record with any data and trigger.
Page 243 Saving the drive recorder data in manual setting mode
Method of reading recorded data
Drive recorder data can be read with an engineering tool (MR Configurator2) via a network or USB connection.
A connection example is shown below.
• Transferring files with direct connection (USB/MR Configurator2)
Servo amplifier
Drive recorder
data
• Transferring files with direct connection or via a hub (Ethernet/GX LogViewer)
To read recorded data from the drive recorder by using the FTP server function, use a network supporting the function.
Servo amplifier
Drive recorder
data
4 APPLICABLE FUNCTIONS
244
4.6 Drive recorder
USB cable
Ethernet hub
Ethernet cable
FTP server
Ethernet cable
FTP client
Log file
Personal computer
Engineering tool
MR Configurator2
Personal computer
Engineering tool
GX LogViewer

Advertisement

Table of Contents
loading

Table of Contents