Operation status at warning occurrence [G] [WG]

The following shows the status of servo amplifiers at a warning occurrence.
Status
The No. of the warning that has occurred is shown on the 7-segment LED.
The operation is continued. However, when a warning that stops the servo motor occurs, the
servo motor is stopped using the method determined by the warning.
Output device signals such as WNG (Warning) are turned off. In addition, at an occurrence of
a warning to stop the servo motor, WNGSTOP (Motor stop warning) is turned off.
The occurrence status of alarms and warnings can be monitored with MR Configurator2 or via
a network.

Operation status at warning occurrence [A]

The following shows the status of servo amplifiers at a warning occurrence.
Status
The No. of the warning that has occurred is shown on the 7-segment LED.
The operation is continued. However, when a warning that stops the servo motor occurs, the
servo motor is stopped using the method determined by the warning.
Output device signals such as WNG (Warning), ALMWNG (Malfunction/Warning) are turned
off. In addition, at an occurrence of a warning to stop the servo motor, WNGSTOP (Motor stop
warning) is turned off.
The occurrence status of alarms and warnings can be monitored with MR Configurator2.
3 BASIC FUNCTION
122
3.14 Alarm function
Reference
Refer to "Switch setting and display of the servo amplifier" in
the User's Manual (Introduction).
Page 125 Stop method at occurrence of alarms/warnings
Page 123 Alarm history [G] [WG]
Reference
Page 125 Stop method at occurrence of alarms/warnings
Page 125 Alarm history [A]