FUTABA T10PX Full Manual page 72

Digital proportional r/c systems
Hide thumbs Also See for T10PX:
Table of Contents

Advertisement

6
During the 20 seconds link mode, press the receiver for at least 2 seconds. The LED
blinks red and then changes to a greenish red
makes a beeping sound and the message "Link with receiver" appears on the screen,
release the receiver push switch. This ends reading of mutual ID and displays the
memorized receiver ID number on the T10PX screen. Power cycle the receiver. If the
"Receiver not found" error screen is displayed, linking failed. Check the set contents and
repeat the linking operation.
Link established
The link is completed.
7
Once the settings are complete, turn the receiver off and then on again. The response
and battery fail-safe voltage settings will take effect after the receiver is restarted.
*The T10PX and F-4G receiver (R404SBS/R404SBS-E)/T-FHSS receiver memorize the IDs linked last at each
model memory. Since only one receiver ID is memorized at each model memory, multiple F-4G/T-FHSS re-
ceivers cannot be used with the same model memory. When a receiver at the same model memory is changed,
re-linking is necessary even if the receiver is already linked with the transmitter.
*When using multiple F-4G/T-FHSS receivers, link each receiver with each T10PX model memory. However,
one receiver can be linked with multiple model memories.
*The telemetry function communication status can be checked at the T10PX home screen.
Link notice 
WARNING
Do not perform the linking procedure with motor's main wire connected as 
it may result in serious injury.
After the linking is done, please cycle receiver power and check if the receiver 
to be linked is really under the control of the transmitter to be linked.
■ The settings will not be reflected unless restart. 
LINKAGE MENU
72
green steady light. When the T10PX
R404SBS
Link failed
Repeat the linking operation