Konica Minolta AFR-12 General, Mechanical/Electrical page 74

Table of Contents

Advertisement

Symptom
Step No.
The panel
indicates a
misfeed in the
ADF when a
document is
placedon the
Document Feed
Table.
4.3
Rev. 1.0/05.99
Misfeed Detected When Documents are Loaded
Check Item
1
Is there still a document in
the ADF?
2
Carry out the unit test for the
Registration Sensor (PWB-
B) to check whether it
functions properly.
3
Does the voltage across
CN5-5 on PWB-A and GND
change from "H" to "L" when
the light is blocked with a
piece of paper?
4
Carry out the unit test for the
Size Sensor (PWB-C) to
check whether it functions
properly.
5
Does the voltage across
CN3-3, 3-4 and 3-5 on
PWB-A and GND change
from 5 VDC to 0 VDC when
the light is blocked with a
piece of paper?
6
Does the actuator of PWB-C
operate properly?
T-7
Result
Action
YES
Remove the document.
YES
Go to step 4.
YES
Replace PWB-A.
NO
Replace PWB-B.
YES
Go to step 6.
YES
Replace PWB-A.
NO
Replace PWB-C.
YES
Repair or replace the actuator.
AFR-12/AF-5