3.2.15
Adjustment of the Distance between Separator Rollers
1. Open the Take-Up Cover and loosen the four screws of the Separator Guide
Plate.
2. Cut out a piece of paper of approx. 150 mm by 50 mm and place it between the
Guide Plate and Roller.
3. While gently holding down the Separator Guide Mount Plate (press the Guide
as strongly as the spring pressure), tighten the two screws to the Mount Plate.
4. Tighten the two screws that secure 2nd Separator Guide Plate in position.
5. Loosen the two screws on the 2nd Separator Guide Plate Mount Plate. Raise
the mount plate as far as it will go and, keeping the mount plate in that position,
tighten the two screws.
6. Loosen the two screws that secure 2nd Separator Guide Plate in position. Raise
the guide plate as far as it will go and, keeping the plate in that position, tighten
the two screws.
3.2.16
AFR-12/AF-5
2nd Separator Guide Plate
D-22
Separator Guide Plate
Rev. 1.0/05.99