Konica Minolta AFR-12 General, Mechanical/Electrical page 61

Table of Contents

Advertisement

3.2.11
Adjustment of Document Pressure Solenoid SOL2
Requirement
The clearance between the Guide Plate and Weight Lever should be approximately
2 ± 1 mm.
1. Remove the Document Take-Up Unit Assy, and place it on a table.
2. Loosen two screws.
3. While pushing the Plunger towards the Solenoid (up to the position at which the
Plunger stops), move the Solenoid so that the clearance between the Guide
Plate and Weight Lever is within the specified range.
When moving the Solenoid, make sure that the Plunger is pushed towards the
Solenoid and that there is no play between the Plunger and Weight Lever.
AFR-12/AF-5
NOTE
NOTE
D-18
Rev. 1.0/05.99